CooperSurgical, Inc.

CooperSurgical, Inc.: 83 FDA recall reports

Every medical device recall the FDA has published for CooperSurgical, Inc.. The fault, and how the agency graded it.

83Reports
0Class I
34Ongoing
2025-07-30Most recent

What the classes mean

The FDA sorts every recall into one of three classes. The class is the whole story. It is also the part people skip.

ClassWhat the FDA is saying
Class IThere is a reasonable probability that using this will cause serious harm or death.
Class IIIt may cause temporary or reversible harm. Serious harm is unlikely.
Class IIIIt breaks a rule but is unlikely to hurt anyone. Often a labelling fault.

Class II is the bulk of every list here. That matters. A long list of Class II says something different from one Class I.

By class

ClassReports
Class II73
Class III10

By year reported

YearReports
20146
201515
20163
20171
20185
201911
20205
202111
20225
20235
202413
20253
Checking whether it affects you

The lot or code number is what matters. Not the product name. A recall covers specific lots. Yours may not be one of them.

Check the code on your package against the report. The FDA keeps the current list at fda.gov/safety/recalls.

The reports

The text below is quoted from the FDA record word for word.

Endosee System Convenience Kit with IV Tube. Model Number: ES-TRAY-IV. Endosee System Convenience Kit with

Z-2137-2025  ·  Class II  ·  reported 2025-07-30  ·  Ongoing

Why it was recalled
The HSG Procedure Trays and Endosee System Convenience Kits contain non-sterile iodine pouches, however the peel away lid labels incorrectly identify the iodine pouches as sterile.
Product
Endosee System Convenience Kit with IV Tube. Model Number: ES-TRAY-IV. Endosee System Convenience Kit with IV Tube.
Where it went
US Nationwide distribution including in the states of AL, AR, AZ, CA, CO, CT, DE, FL, GA, HI, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, and Washington DC.
How much
475 units

Endosee System Convenience Kit. Model Number: ES-TRAY. Endosee System Convenience Kit

Z-2136-2025  ·  Class II  ·  reported 2025-07-30  ·  Ongoing

Why it was recalled
The HSG Procedure Trays and Endosee System Convenience Kits contain non-sterile iodine pouches, however the peel away lid labels incorrectly identify the iodine pouches as sterile.
Product
Endosee System Convenience Kit. Model Number: ES-TRAY. Endosee System Convenience Kit
Where it went
US Nationwide distribution including in the states of AL, AR, AZ, CA, CO, CT, DE, FL, GA, HI, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, and Washington DC.
How much
991 units

HSG Procedure Tray. Model Number: 6050T. The HSG Procedure Tray is for use in hysterosalpingography and so

Z-2135-2025  ·  Class II  ·  reported 2025-07-30  ·  Ongoing

Why it was recalled
The HSG Procedure Trays and Endosee System Convenience Kits contain non-sterile iodine pouches, however the peel away lid labels incorrectly identify the iodine pouches as sterile.
Product
HSG Procedure Tray. Model Number: 6050T. The HSG Procedure Tray is for use in hysterosalpingography and sonohysterography procedures.
Where it went
US Nationwide distribution including in the states of AL, AR, AZ, CA, CO, CT, DE, FL, GA, HI, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, and Washington DC.
How much
171 units

Brand Name: K-Systems Product Name: G85 Mini Incubator Model/Catalog Number: K22074 Software Version: N/A

Z-0688-2025  ·  Class II  ·  reported 2024-12-25  ·  Ongoing

Why it was recalled
The warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
Product
Brand Name: K-Systems Product Name: G85 Mini Incubator Model/Catalog Number: K22074 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and embryos), at closely regulated and monitored temperatures, during assisted reproduction examination and processing procedures. It may support a more comprehensive growth environment [e.g., temperature, carbon dioxide (CO2) and oxygen (O2) concentration]; it typically has adjustment and monitoring controls. Component: No
Where it went
States: NC, NJ, TX, VA, IL, NY, CA, PA Please note: The countries below, excluding Iraq, all consider these devices to be "lab equipment", not medical devices and are not subject to classification or recall guidelines. Countries: AT, AU, BE, BH, BR, CA, CH, CN, CZ, DE, EG, ES, ET, FR, GB, GH, HU, ID, IE, IL, IN, IQ, IT, JO, JP, KR, KW, LB, MA, MK, MT, NL, NO, PE, PH, PK, PT, QA, RO, RS, SA, SD, SE, SO,TR, TW, TZ, US, ZA
How much
37 units

Brand Name: K-Systems Product Name: T47 Warming Plate Model/Catalog Number: K23054 Software Version: N/A P

Z-0689-2025  ·  Class II  ·  reported 2024-12-25  ·  Ongoing

Why it was recalled
The warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
Product
Brand Name: K-Systems Product Name: T47 Warming Plate Model/Catalog Number: K23054 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and embryos), at closely regulated and monitored temperatures, during assisted reproduction examination and processing procedures. It may support a more comprehensive growth environment [e.g., temperature, carbon dioxide (CO2) and oxygen (O2) concentration]; it typically has adjustment and monitoring controls. Component: No
Where it went
States: NC, NJ, TX, VA, IL, NY, CA, PA Please note: The countries below, excluding Iraq, all consider these devices to be "lab equipment", not medical devices and are not subject to classification or recall guidelines. Countries: AT, AU, BE, BH, BR, CA, CH, CN, CZ, DE, EG, ES, ET, FR, GB, GH, HU, ID, IE, IL, IN, IQ, IT, JO, JP, KR, KW, LB, MA, MK, MT, NL, NO, PE, PH, PK, PT, QA, RO, RS, SA, SD, SE, SO,TR, TW, TZ, US, ZA
How much
22 units

Brand Name: K-Systems Product Name: Multiple/unknown Model/Catalog Number: Multiple/unknown Software Versio

Z-0692-2025  ·  Class II  ·  reported 2024-12-25  ·  Ongoing

Why it was recalled
The warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
Product
Brand Name: K-Systems Product Name: Multiple/unknown Model/Catalog Number: Multiple/unknown Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and embryos), at closely regulated and monitored temperatures, during assisted reproduction examination and processing procedures. It may support a more comprehensive growth environment [e.g., temperature, carbon dioxide (CO2) and oxygen (O2) concentration]; it typically has adjustment and monitoring controls. Component: N/A
Where it went
States: NC, NJ, TX, VA, IL, NY, CA, PA Please note: The countries below, excluding Iraq, all consider these devices to be "lab equipment", not medical devices and are not subject to classification or recall guidelines. Countries: AT, AU, BE, BH, BR, CA, CH, CN, CZ, DE, EG, ES, ET, FR, GB, GH, HU, ID, IE, IL, IN, IQ, IT, JO, JP, KR, KW, LB, MA, MK, MT, NL, NO, PE, PH, PK, PT, QA, RO, RS, SA, SD, SE, SO,TR, TW, TZ, US, ZA
How much
34 units

Brand Name: K-Systems Product Name: G73 Dry Bath Incubator Model/Catalog Number: K22065 Product Description

Z-0687-2025  ·  Class II  ·  reported 2024-12-25  ·  Ongoing

Why it was recalled
The warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
Product
Brand Name: K-Systems Product Name: G73 Dry Bath Incubator Model/Catalog Number: K22065 Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and embryos), at closely regulated and monitored temperatures, during assisted reproduction examination and processing procedures. It may support a more comprehensive growth environment [e.g., temperature, carbon dioxide (CO2) and oxygen (O2) concentration]; it typically has adjustment and monitoring controls. Component: N/A
Where it went
States: NC, NJ, TX, VA, IL, NY, CA, PA Please note: The countries below, excluding Iraq, all consider these devices to be "lab equipment", not medical devices and are not subject to classification or recall guidelines. Countries: AT, AU, BE, BH, BR, CA, CH, CN, CZ, DE, EG, ES, ET, FR, GB, GH, HU, ID, IE, IL, IN, IQ, IT, JO, JP, KR, KW, LB, MA, MK, MT, NL, NO, PE, PH, PK, PT, QA, RO, RS, SA, SD, SE, SO,TR, TW, TZ, US, ZA
How much
106 units

Brand Name: K-Systems Product Name: T47 Warming Plate Model/Catalog Number: K23055 Software Version: N/A P

Z-0690-2025  ·  Class II  ·  reported 2024-12-25  ·  Ongoing

Why it was recalled
The warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
Product
Brand Name: K-Systems Product Name: T47 Warming Plate Model/Catalog Number: K23055 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and embryos), at closely regulated and monitored temperatures, during assisted reproduction examination and processing procedures. It may support a more comprehensive growth environment [e.g., temperature, carbon dioxide (CO2) and oxygen (O2) concentration]; it typically has adjustment and monitoring controls. Component: No
Where it went
States: NC, NJ, TX, VA, IL, NY, CA, PA Please note: The countries below, excluding Iraq, all consider these devices to be "lab equipment", not medical devices and are not subject to classification or recall guidelines. Countries: AT, AU, BE, BH, BR, CA, CH, CN, CZ, DE, EG, ES, ET, FR, GB, GH, HU, ID, IE, IL, IN, IQ, IT, JO, JP, KR, KW, LB, MA, MK, MT, NL, NO, PE, PH, PK, PT, QA, RO, RS, SA, SD, SE, SO,TR, TW, TZ, US, ZA
How much
35 units

Brand Name: K-Systems Product Name: R65 Trolley Model/Catalog Number: K24012 Software Version: N/A Product

Z-0691-2025  ·  Class II  ·  reported 2024-12-25  ·  Ongoing

Why it was recalled
The warming surfaces or incubator well temperatures of the listed products may exceed the desired set temperature. If temperatures exceed the desired set value, the device will alarm appropriately.
Product
Brand Name: K-Systems Product Name: R65 Trolley Model/Catalog Number: K24012 Software Version: N/A Product Description: An electrically-powered device intended to provide suitable warming and/or incubation conditions for reproductive biological materials (e.g., gametes and embryos), at closely regulated and monitored temperatures, during assisted reproduction examination and processing procedures. It may support a more comprehensive growth environment [e.g., temperature, carbon dioxide (CO2) and oxygen (O2) concentration]; it typically has adjustment and monitoring controls. Component: N/A
Where it went
States: NC, NJ, TX, VA, IL, NY, CA, PA Please note: The countries below, excluding Iraq, all consider these devices to be "lab equipment", not medical devices and are not subject to classification or recall guidelines. Countries: AT, AU, BE, BH, BR, CA, CH, CN, CZ, DE, EG, ES, ET, FR, GB, GH, HU, ID, IE, IL, IN, IQ, IT, JO, JP, KR, KW, LB, MA, MK, MT, NL, NO, PE, PH, PK, PT, QA, RO, RS, SA, SD, SE, SO,TR, TW, TZ, US, ZA
How much
43 units

Stainless Steel Sims Uterine Sound, Part Number 64-601

Z-3189-2024  ·  Class II  ·  reported 2024-10-02  ·  Ongoing

Why it was recalled
During the manufacturing process the devices were laser-marked with the incorrect part number.
Product
Stainless Steel Sims Uterine Sound, Part Number 64-601
Where it went
Worldwide distribution - US Nationwide and the countries of Armenia, Bahrain, Canada, Hong Kong, India, New Zealand, Qatar, Sweden.
How much
657 units

Origio Sperm Wash Medium Pack of Five 60ml bottles - Intended for washing of spermatozoa. Part Number: 8405

Z-3298-2024  ·  Class II  ·  reported 2024-10-02  ·  Ongoing

Why it was recalled
Low concentration of sodium pyruvate in the wash could compromise gamete development
Product
Origio Sperm Wash Medium Pack of Five 60ml bottles - Intended for washing of spermatozoa. Part Number: 84055060D
Where it went
Worldwide distribution - US Nationwide.
How much
770 units

Origio Sperm Wash Medium Pack of Ten 10ml bottles - Intended for washing of spermatozoa Part Number: 840510

Z-3296-2024  ·  Class II  ·  reported 2024-10-02  ·  Ongoing

Why it was recalled
Low concentration of sodium pyruvate in the wash could compromise gamete development
Product
Origio Sperm Wash Medium Pack of Ten 10ml bottles - Intended for washing of spermatozoa Part Number: 84051010A
Where it went
Worldwide distribution - US Nationwide.
How much
980 units

Origio Sperm Wash Medium Pack of Five 60ml bottles - Intended for washing of spermatozoa. Part Number: 8405

Z-3297-2024  ·  Class II  ·  reported 2024-10-02  ·  Ongoing

Why it was recalled
Low concentration of sodium pyruvate in the wash could compromise gamete development
Product
Origio Sperm Wash Medium Pack of Five 60ml bottles - Intended for washing of spermatozoa. Part Number: 84055060A
Where it went
Worldwide distribution - US Nationwide.
How much
2680 units

Silver-Plated Copper Sims Uterine Sound, Part Number 64-600

Z-3188-2024  ·  Class II  ·  reported 2024-10-02  ·  Ongoing

Why it was recalled
During the manufacturing process the devices were laser-marked with the incorrect part number.
Product
Silver-Plated Copper Sims Uterine Sound, Part Number 64-600
Where it went
Worldwide distribution - US Nationwide and the countries of Armenia, Bahrain, Canada, Hong Kong, India, New Zealand, Qatar, Sweden.
How much
468 units

global Medium, Model Numbers LGGG-020 (20mL bottle), LGGG-050 (50mL bottle), LGGG-100 (100mL bottle). Intended

Z-1089-2024  ·  Class II  ·  reported 2024-02-21  ·  Ongoing

Why it was recalled
The firm has become aware of a sudden increase in complaints for three associated lots. Performance issues may lead to impaired embryo development prior to the blastocyst stage.
Product
global Medium, Model Numbers LGGG-020 (20mL bottle), LGGG-050 (50mL bottle), LGGG-100 (100mL bottle). Intended use: Culture of human embryos from zygote to blastocyst, embryo transfer.
Where it went
Worldwide - US Nationwide including in the states of AL, AZ, CA, CO, FL, GA, IL, IN, IA, KS, KY, LA, MD, MA, MI, MO, NV, NJ, NM, NY, NC, OH, OK, OR, PA, RI, TN, TX, UT, VT, VA, WA, WV and the countries of Canada, Brazil, Mexico, Argentina, Hong Kong, Japan, Turkey, Netherlands, Belgium, Spain, Taiwan, United Kingdom, Austria, Georgia, France, Denmark, Greece, Saudi Arabia, Thailand, New Zealand, Estonia, Poland, Jordan, and Germany.
How much
994 total (481 US; 513 OUS)

Box as labeled: Regard, Carter-Thomason CloseSure System XL, REF 733776, Quantity 1 Box of 3 Systems. Kit as

Z-0985-2024  ·  Class II  ·  reported 2024-02-14  ·  Ongoing

Why it was recalled
Incorrect component descriptions within the "Contents" section on the Tyvek lid for individual kit trays.
Product
Box as labeled: Regard, Carter-Thomason CloseSure System XL, REF 733776, Quantity 1 Box of 3 Systems. Kit as labeled: Regard, Carter-Thomason CloseSure System, REF 733776, Contents: One (1) Carter-Thomason Suture Passer, One (1) 5 mm Pilot Guide, One (1) 10/12 mm Pilot Guide.
Where it went
US Nationwide distribution in the state of MO.
How much
127 boxes, 3 kits per box (381 kits total)

Cooper Surgical H/S ELLIPTOSPHERE CATH 5 Fr -For administering contrast media during Hysterosalpingography or

Z-0502-2024  ·  Class II  ·  reported 2023-12-13  ·  Ongoing

Why it was recalled
Incorrect bonding material used for assembly of the catheter, may fail, resulting in detachment of component parts, broken components, or leakage. This breakage may result in delay of procedure
Product
Cooper Surgical H/S ELLIPTOSPHERE CATH 5 Fr -For administering contrast media during Hysterosalpingography or Hysterosonography procedures to detect uterine pathology such as polyps, fibroids, adhesions or endometrial thickening, and/or patency of fallopian tubes. Model: 61-3005
Where it went
Nationwide Foreign: BELGIUM CANADA MALAYSIA NETHERLANDS SPAIN SWEDEN SWITZERLAND
How much
73 units

Cooper Surgical H/S ELLIPTOSPHERE CATH 5 FR Set-For administering contrast media during Hysterosalpingography

Z-0503-2024  ·  Class II  ·  reported 2023-12-13  ·  Ongoing

Why it was recalled
Incorrect bonding material used for assembly of the catheter, may fail, resulting in detachment of component parts, broken components, or leakage. This breakage may result in delay of procedure
Product
Cooper Surgical H/S ELLIPTOSPHERE CATH 5 FR Set-For administering contrast media during Hysterosalpingography or Hysterosonography procedures to detect uterine pathology such as polyps, fibroids, adhesions or endometrial thickening, and/or patency of fallopian tubes Model: 61-4005
Where it went
Nationwide Foreign: BELGIUM CANADA MALAYSIA NETHERLANDS SPAIN SWEDEN SWITZERLAND
How much
169 units

CooperSurgical H/S CATHETER SET FR 5 with Integated Stylet Model: 61-4005S For administering contrast media

Z-0504-2024  ·  Class II  ·  reported 2023-12-13  ·  Ongoing

Why it was recalled
Incorrect bonding material used for assembly of the catheter, may fail, resulting in detachment of component parts, broken components, or leakage. This breakage may result in delay of procedure
Product
CooperSurgical H/S CATHETER SET FR 5 with Integated Stylet Model: 61-4005S For administering contrast media during Hysterosalpingography or Hysterosonography procedures to detect uterine pathology such as polyps, fibroids, adhesions or endometrial thickening, and/or patency of fallopian tubes
Where it went
Nationwide Foreign: BELGIUM CANADA MALAYSIA NETHERLANDS SPAIN SWEDEN SWITZERLAND
How much
90 units

Global Total LP single step medium, 60mL, bicarbonate-buffered media for D1-5 embryo culture and transfer, Ref

Z-1348-2023  ·  Class II  ·  reported 2023-04-12  ·  Ongoing

Why it was recalled
It has come to CooperSurgical's attention that the affected Product may contain a medium other than the Global Total LP single step medium which does not contain the protein source required for embryo culture and development.
Product
Global Total LP single step medium, 60mL, bicarbonate-buffered media for D1-5 embryo culture and transfer, Reference Number H5GT-060
Where it went
Worldwide - US Nationwide distribution in the states of NY, UT and the countries of Argentina, Belgium, Bulgaria, Ecuador, France, Germany, Hong Kong, Italy, Malaysia, Mexico, Peru, Singapore, Spain, Switzerland, Thailand, Turkey, the United Kingdom.
How much
190 units

BIOPSY MEDIUM 10ML, Reference Number 10620010 A, used for blastomere biopsy of cleavage stage embryos for Pre-

Z-1044-2023  ·  Class II  ·  reported 2023-02-08  ·  Ongoing

Why it was recalled
The affected product may contain a medium other than the Biopsy Medium. There is a risk that use of the Product from this lot could cause degradation of the embryo.
Product
BIOPSY MEDIUM 10ML, Reference Number 10620010 A, used for blastomere biopsy of cleavage stage embryos for Pre-implantation Genetic Diagnosis (PGD)
Where it went
Global Distribution including countries of: Bahrain, Belgium, Bulgaria, Egypt, France, Georgia, Greece, Hong Kong, Iran, Iraq, Israel, Japan, Jordan, Kazakhstan, Kuwait, Lebanon, Libya, Nigeria, Oman, Pakistan, Poland, Republic of North Macedonia, Saudi Arabia, Slovenia, Spain, Thailand, Turkey, Turkmenistan, and United Arab Emirates.
How much
489 units

NEO-fit Neonatal Endotracheal Tube Grip, Part Number 42-2540

Z-0223-2023  ·  Class II  ·  reported 2022-11-16  ·  Ongoing

Why it was recalled
Firm has received 11 complaints involving a loose or detached metal clips, including 3 cases where the metal clip was ingested by the patient, and 3 cases where the metal clip was removed from the patient's mouth. In one case, the patient suffered a laceration to the throat.
Product
NEO-fit Neonatal Endotracheal Tube Grip, Part Number 42-2540
Where it went
Worldwide distribution: US (Nationwide) including Puerto Rico; and countries (foreign) of: Australia, Bahrain, Belgium, Bulgaria, Canada, Colombia, Cyprus, Ecuador, Germany, Greece, Hong Kong, Hungary, India, Ireland, Italy, Malaysia, Malta, Netherlands, New Zealand, Saudi Arabia, Singapore, Turkey, Philippines, Qatar, United Arab Emirates, and United Kingdom.
How much
220,500 devices

Humidifier bottle and syringe filter kit (6 count of each) for the BT37 Mark II Benchtop Incubator (AY200246)

Z-1823-2022  ·  Class II  ·  reported 2022-10-05  ·  Ongoing

Why it was recalled
There is a potential breach to the sterile barrier containing the Humidifier Bottles due to the packaging of the filter box located inside the bottle packaging. Damage to the sterile barrier may result in use of an unsterilized device, which may cause contamination and degradation or loss of embryo during incubation.
Product
Humidifier bottle and syringe filter kit (6 count of each) for the BT37 Mark II Benchtop Incubator (AY200246)
Where it went
Domestic distribution to the following states: AL AZ CA CT DE FL GA HI IL KS MA MI MN MO NJ NY OH OR SC TX VA VT WA WI WV Foreign distribution to Barbados, Canada, Chile, Micronesia Federate, and Panama.
How much
5,182 kits

Humidifier bottle and syringe filter kit (6 count of each) for the BT37 Mark I Benchtop Incubator (AY102295).

Z-1822-2022  ·  Class II  ·  reported 2022-10-05  ·  Ongoing

Why it was recalled
There is a potential breach to the sterile barrier containing the Humidifier Bottles due to the packaging of the filter box located inside the bottle packaging. Damage to the sterile barrier may result in use of an unsterilized device, which may cause contamination and degradation or loss of embryo during incubation.
Product
Humidifier bottle and syringe filter kit (6 count of each) for the BT37 Mark I Benchtop Incubator (AY102295). The Mark I model is no longer produced, but the legacy humidifier bottle component design can also be used with the BT37 Mark II Benchtop Incubator.
Where it went
Domestic distribution to the following states: AL AZ CA CT DE FL GA HI IL KS MA MI MN MO NJ NY OH OR SC TX VA VT WA WI WV Foreign distribution to Barbados, Canada, Chile, Micronesia Federate, and Panama.
How much
5,182 kits

LifeGlobal Fast Freeze Thawing Kit, Model No. GFT5-055

Z-1421-2022  ·  Class II  ·  reported 2022-07-27  ·  Ongoing

Why it was recalled
There was translation error in the Spanish version of the IFU where the Spanish version instructs the user to leave the blastocyte to air thaw for 5 minutes rather than the correct 5 seconds as indicated in the English version.
Product
LifeGlobal Fast Freeze Thawing Kit, Model No. GFT5-055
Where it went
Domestic: USA AL, AZ, CA, CT, FL, GA, ID, IL, IN, KS, MA, MD, MI, MN, MO, MT, NC, NE, NJ, NV, NY, OH, OK, OR, PA, SC, TX, UT, VT, WA, WI, International: Belgium, Canada, Croatia, Netherlands, Portugal, Spain
How much
403 units

VITRIGUARD, CARRIER, CLEAR; Model. No. 43782001 The VitriGuard device is a cryopreservation storage device

Z-1108-2022  ·  Class II  ·  reported 2022-05-25  ·  Ongoing

Why it was recalled
Products in this lot may have compromised barrier seals, introducing a risk to sterility.
Product
VITRIGUARD, CARRIER, CLEAR; Model. No. 43782001 The VitriGuard device is a cryopreservation storage device composed of a stick and cap.
Where it went
Domestic distribution to AZ, CA, FL, IL, MI, MO, NY, OR, TX, and WV. No foreign distribution.
How much
2,340 (US only)

Quantum 2000 Electrosurgical Generators Cooper Surgical Part Number: 909075

Z-0261-2022  ·  Class II  ·  reported 2021-11-24  ·  Ongoing

Why it was recalled
Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case.
Product
Quantum 2000 Electrosurgical Generators Cooper Surgical Part Number: 909075
Where it went
US Nationwide Distribution Foreign: ARMENIA, BOLIVIA, CAMBODIA, CANADA, CHILE, CHINA, COSTA RICA, DOMINICAN REPUBLIC, ECUADOR, ENGLAND, GERMANY, HONG KONG, INDIA, INDONESIA, IRAN, ITALY, JORDAN, KENYA, MALAYSIA, MAURITIUS, MEXICO, NEW ZEALAND, NICARAGUA, NIGERIA, PHILIPPINES, PUERTO RICO, QATAR, RWANDA, SINGAPORE, SOUTH AFRICA, SRI LANKA, TAIWAN, TANZANIA, THAILAND, TRINIDAD, TURKEY, UGANDA, UNITED ARAB EMIRATES, VIETNAM
How much
193 Units

LEEP PRECISION Integrated System, 220V CooperSurgical part numbers: LP-10-220

Z-0258-2022  ·  Class II  ·  reported 2021-11-24  ·  Ongoing

Why it was recalled
Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case.
Product
LEEP PRECISION Integrated System, 220V CooperSurgical part numbers: LP-10-220
Where it went
US Nationwide Distribution Foreign: ARMENIA, BOLIVIA, CAMBODIA, CANADA, CHILE, CHINA, COSTA RICA, DOMINICAN REPUBLIC, ECUADOR, ENGLAND, GERMANY, HONG KONG, INDIA, INDONESIA, IRAN, ITALY, JORDAN, KENYA, MALAYSIA, MAURITIUS, MEXICO, NEW ZEALAND, NICARAGUA, NIGERIA, PHILIPPINES, PUERTO RICO, QATAR, RWANDA, SINGAPORE, SOUTH AFRICA, SRI LANKA, TAIWAN, TANZANIA, THAILAND, TRINIDAD, TURKEY, UGANDA, UNITED ARAB EMIRATES, VIETNAM
How much
75 Units

Quantum 2000 Electrosurgical Generators Cooper Surgical Part Number: 909075-05W

Z-0263-2022  ·  Class II  ·  reported 2021-11-24  ·  Ongoing

Why it was recalled
XXX
Product
Quantum 2000 Electrosurgical Generators Cooper Surgical Part Number: 909075-05W
Where it went
US Nationwide Distribution Foreign: ARMENIA, BOLIVIA, CAMBODIA, CANADA, CHILE, CHINA, COSTA RICA, DOMINICAN REPUBLIC, ECUADOR, ENGLAND, GERMANY, HONG KONG, INDIA, INDONESIA, IRAN, ITALY, JORDAN, KENYA, MALAYSIA, MAURITIUS, MEXICO, NEW ZEALAND, NICARAGUA, NIGERIA, PHILIPPINES, PUERTO RICO, QATAR, RWANDA, SINGAPORE, SOUTH AFRICA, SRI LANKA, TAIWAN, TANZANIA, THAILAND, TRINIDAD, TURKEY, UGANDA, UNITED ARAB EMIRATES, VIETNAM
How much
154 Units

LEEP PRECISION Generator 220V Cooper Surgical Part Number: LP-20-220

Z-0260-2022  ·  Class II  ·  reported 2021-11-24  ·  Ongoing

Why it was recalled
Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case.
Product
LEEP PRECISION Generator 220V Cooper Surgical Part Number: LP-20-220
Where it went
US Nationwide Distribution Foreign: ARMENIA, BOLIVIA, CAMBODIA, CANADA, CHILE, CHINA, COSTA RICA, DOMINICAN REPUBLIC, ECUADOR, ENGLAND, GERMANY, HONG KONG, INDIA, INDONESIA, IRAN, ITALY, JORDAN, KENYA, MALAYSIA, MAURITIUS, MEXICO, NEW ZEALAND, NICARAGUA, NIGERIA, PHILIPPINES, PUERTO RICO, QATAR, RWANDA, SINGAPORE, SOUTH AFRICA, SRI LANKA, TAIWAN, TANZANIA, THAILAND, TRINIDAD, TURKEY, UGANDA, UNITED ARAB EMIRATES, VIETNAM
How much
75 Units

Showing the 30 most recent of 83. The rest are searchable at the FDA enforcement report database.

Read these counts with three things in mind

A firm with more recalls usually makes more products. A contract packer runs hundreds of lines. It will out-recall a company with one product whatever either does. This is not a safety ranking.

Most recalls here are voluntary. A firm found its own fault and pulled the stock. That is the system working. It lands in this database looking the same as a recall the FDA had to push for.

Terminated means the FDA considers the recall finished. It is not a verdict. It does not mean anyone was harmed.

Source: openFDA enforcement reports, retrieved 2026-08-05. FDA dataset last updated 2026-07-29.

← All device recalls